PRM-TAIWAN

High Pressure Proportional Regulator/Controller (0-18bar.0-70bar)

Classification : Proportional Pressure Regulator
Country: Taiwan
Phone: +886-4-24874219
Fax: +886-4-24864269
Contact Person: Jerry Wu
Video Inquiry Now

Product Serial: QKL-B4H

QKL-B4H pressure controller is a device used to maintain or control the pressure of a fluid (such as gas or liquid) within a desired range. It is commonly used in industrial and manufacturing processes where maintaining a constant pressure is critical to ensuring quality and consistency in the end product.

KaoLu's controller features high speed, high accuracy 0.05% F.S , and high resolution 1kPa, and most importantly ultra-stable at target pressure. Customers have used our electronic controller to replace expensive dekstop pressure controller (consult for customised spec).

Pressure controllers typically consist of a pressure sensor, a control circuit, and an actuator. The pressure sensor measures the pressure of the fluid and sends a signal to the control circuit. The control circuit then compares the measured pressure to the desired set point and sends a signal to the actuator to adjust the pressure accordingly.

There are different types of pressure controllers, including mechanical, pneumatic, and electronic controllers. Mechanical controllers use a mechanical feedback mechanism to control the pressure, while pneumatic controllers use air pressure to adjust the pressure of the fluid. Electronic controllers use electronic feedback to adjust the pressure, and they can be more precise and flexible than mechanical or pneumatic controllers.

Some common applications include controlling the pressure in pipelines, regulating the pressure of gases in a semi-conductor equipment such a MOCVD equipment, or maintaining the pressure in a pneumatic system.

Electronic Pressure controllers are widely used in various industrial and scientific applications where precise control of pressure is required. Some common applications are:

  1. Manufacturing: used in manufacturing processes to control and regulate pressure in different stages of the production process, such as injection molding, extrusion, and coating.

  2. Research and Development: used in research and development laboratories to create and maintain precise atmospheric conditions required for experiments and testing.

  3. HVAC Systems: used in heating, ventilation, and air conditioning (HVAC) systems to maintain proper air flow and pressure in the system.

  4. Medical Equipment: used in medical equipment, such as respirators, anesthesia machines, and blood pressure monitors, to maintain a constant and precise pressure.

  5. Automotive: used in automotive systems, such as fuel injection, airbag deployment, and tire pressure monitoring, to control and regulate pressure.

  6. Semiconductor: used in MOCVD applications to maintain the pneuamtic pressure in and flow rate.

  7. Food and Beverage Industry: used in food and beverage production and processing to maintain proper pressure in different stages of the process, such as bottling and canning.

Overall, electronic pressure controllers play a critical role in maintaining precise pressure in various industrial and scientific applications, ensuring the safety, quality, and reliability of the end product.

Features
◆ Small Size
◆ High Precision
◆ High Sensitivity
◆ Wide Pressure Range

Industrial application
◆ Laser Cutter
◆ Leak Tester
◆ Tension Control
◆ PET bottle molding machine
◆ Multi-Stage Pressure Control

Type B4H-P18(261psi) B4H-P60(870psi) B4H-P70(1015psi)
Input Signal 0-10V / 4-20mA /RS485
Output Range 0-18bar (260 psi) 0-60bar (870 psi) 0-70bar(1015 psi)
Supply Pressure Max 20bar (290 psi) 65bar (942 psi) 74bar(1073 psi)
Monitor Output 0-10V / 4-20mA
Supply DC24V (≦4W)
Response 200 msec
Medium Clean compressed air or with 5 μm filter
Repeatability ±0.25% F.S. ±0.25% F.S. ±0.25% F.S.
Hysteresis ±0.25% F.S. ±0.25% F.S. ±0.25% F.S.
Linearity ±0.25% F.S. ±0.25% F.S. ±0.25% F.S.
Accuracy ±0.25% F.S. ±0.25% F.S. ±0.25% F.S.
Sensitive 0.1bar 0.5bar 0.5bar
Flow Rate 40L/min @ 18bar 145L/min @ 60bar 170L/min @ 70bar
Temp. Range(Operating) -196 ~ 70 ⁰C ( -320 ~ -158 ⁰F)
Port Size 1/8"PT
Manifold Material Aluminum
Electrical Connection M12 Connector(2m)
Ingress Protection IP 65
Weight 800 g
Series Type   Input Signal   Monitor Output   Mounting Bracket   Dislay Unit   Display Unit
QKL- B4H - E - C - M - P70 - U
  B4H: Low flow with internal feedback   *E: 0-10V   C:0-10V   M:M type   P18:0 - 18 bar, 80LPM   S:psi
  A: 4-20mA A:4-20mA L:L type P60:0 - 60 bar, 160LPM U:bar
  R: RS485 Modbus     P70:0 - 70 bar, 200LPM  

*For Command Signal type 0-10V, the minimum driving current is 50mA.
★Please consult us for customized pressure range.


The wiring diagram shows from top view.

No. Color Function
1 Blue 24V DC Power (-)
Output monitor (-)
2nd loop transducer 0 -10 V (-)
2 Brown 24V DC Power (+)
2nd loop transducer 4 - 20 mA (+)
3 Black Monitor output (+)
4 White 0-10 V Command (+)
4-20 mA Command (+)
5 Gray RS485(D-)
6 Green 2nd loop transducer 0 -10 V (+)
2nd loop transducer 4 - 20 mA (-)
7 purple - Command (-)
8 Red RS485(D+)

** Warning: Do not rotate the connection socket when connected, to avoid damage to the internal sensor.